Fresh air, extract and moisture control designed with the fabric
Residential Building Ventilation London

Renovation can make a home warmer and more airtight, so ventilation must be designed with the upgraded fabric and intended occupancy.
Kitchens, bathrooms, utilities and other moisture-producing spaces need effective extract, while habitable rooms require suitable supply or background air under the project strategy. Existing chimneys, window vents and leakage should not be assumed to provide controlled ventilation after windows, roofs and insulation are upgraded.
System choice may include intermittent extract, continuous mechanical extract, positive input or heat-recovery ventilation depending on the property and design. Each has airflow, duct, noise, maintenance and control requirements. A technology label alone does not establish that it suits the layout.
Duct routes are coordinated with structure, fire protection, ceilings, roof build-ups and external terminals. Bends, restrictions and long runs affect fan performance and noise. Equipment, filters, dampers and controls remain accessible for commissioning and regular maintenance.
Design air paths, not isolated fans
Ventilation strategy
Define supply, transfer and extract paths for the whole dwelling using the proposed occupancy and fabric performance.
Wet-room extract
Coordinate fan or valve position, design flow, controls, make-up air and discharge route with ceilings and waterproofing.
Duct design
Size and route ducts with manageable bends, supports, insulation, condensation control and suitable external terminals.
Noise control
Select equipment, velocities, mounts and attenuators where required so design airflow remains acceptable in use.
Fire and structure
Coordinate penetrations, dampers or fire stopping and avoid unapproved cutting of beams, joists or protected linings.
Commissioning and access
Measure airflow, set controls and leave filters, fans and access panels practical for cleaning and replacement.
What genuine project evidence shows
First-fix photographs show the limited space shared by cables, pipes, structure and ventilation routes. Finished interiors show why access panels and terminals must be placed deliberately. Both stages are needed to achieve airflow without compromising ceilings or joinery.
Replacement windows, internal doors and fitted joinery can alter intended air paths late in the programme. Final commissioning therefore uses the completed building condition. If measured flow or noise is outside the design, restrictions, controls and installation details are investigated before handover.





Verify performance at completion
Fans are commissioned at the terminals under the installed condition, with doors, background ventilators and controls set as intended. Design flow cannot be confirmed from motor noise or a hand held near the grille.
The homeowner receives operating guidance: normal modes, boost controls, filter changes, cleaning and signs of a fault. Maintenance access is part of the design; an efficient unit cannot remain efficient if filters or condensate drains are unreachable.
A controlled sequence
- Review fabric upgrades, rooms and occupancy.
- Select the dwelling ventilation strategy.
- Coordinate air paths, ducts, terminals and controls.
- Resolve structure, fire, acoustic and condensation details.
- Install and inspect before enclosure.
- Measure, balance and commission airflow.
- Hand over settings and maintenance requirements.
Common mistakes to avoid
- Adding individual fans without a whole-home air path.
- Using flexible duct for long restricted runs.
- Terminating extract inside roofs or voids.
- Hiding filters and fans without access.
- Skipping measured airflow commissioning.
Frequently asked questions
Why does insulation affect ventilation?
Improved fabric can reduce uncontrolled leakage. A designed ventilation system then becomes more important for moisture, pollutants and indoor air quality.
Is MVHR suitable for every renovation?
No. Airtightness, space, duct routes, maintenance and cost need assessment. Other strategies may be more practical for some existing homes.
Can bathroom extract discharge into the loft?
It should discharge to a suitable external terminal under the design. Releasing moist air into a roof void can create condensation and damage.
Why are doors part of the air path?
Air often needs to transfer from supply rooms to extract rooms. Door undercuts or designed grilles may be required so closed doors do not block flow.
Who commissions ventilation?
A competent person measures and records system performance as required for the project, with controls set and information supplied for handover.